Data Centers

Every facility type fails differently. We work across all of them.

Hyperscale, HPC and AI, colocation, edge, and enterprise. More megawatts, higher densities, and capacity sold before the concrete is poured.

Segment

Hyperscale: when the campus runs to hundreds of megawatts

At hyperscale, the challenge is not any single system. It is holding quality and schedule discipline across hundreds of parallel workstreams, often with multiple general contractors, thousands of trade workers, and repeating scopes that should get faster with each building but frequently do not.

Hyperscale builds represent the bulk of active PGCIS work. We understand the delivery model: repeating designs, aggressive deployment schedules, and owners who need predictable turnover dates because the capacity is already committed. Our Quality in Action™ program was built for this environment. Repeating floor plates are exactly where FOAK-Right™ installation workshops pay back the most, because every crew and every building that follows benefits from what you learned on the first one.

We provide commissioning authority, quality program management, and construction management for hyperscale clients across the full range of testing phases, from factory acceptance through full load under live conditions. We sit inside the delivery team rather than alongside it, which means problems get resolved at the cost of construction, not the cost of commissioning.

Segment

HPC and AI: high density, low tolerance for error

You are installing GPU clusters at 30 kW to 200 kW per rack or higher. The cooling infrastructure required to support that density is less standardized and less forgiving than what a traditional air-cooled facility requires.

Commissioning a liquid-cooled AI cluster requires specific expertise in thermal management validation, coolant distribution unit sequencing, leak detection and containment, and the interaction between liquid and air systems in hybrid environments. Errors here do not just delay commissioning. They risk damaging equipment that can cost tens of millions of dollars to replace.

We have worked across direct-to-chip, single-phase immersion, two-phase immersion, and rear-door heat exchanger systems. We validate power distribution to high-density racks including busway, power distribution units, and rack power panels designed for sustained high-draw GPU loads. We run pre-power-on quality checks that catch installation errors before they become equipment incidents.

Segment

Colocation: quality failures don't stay contained

Multi-tenant colocation adds a coordination layer that single-tenant builds do not have. When a build-out touches shared infrastructure, or when multiple tenant fit-outs are running simultaneously in a live facility, a quality problem in one suite becomes everyone's problem.

We provide commissioning program management and quality oversight for wholesale colocation operators managing dedicated customer suites and build-to-suit capacity. We also support the owner's representation role during lease negotiations, where the commitments being made need to be grounded in what the facility has actually been tested to do, not in what the design assumed it would do.

For colocation developers, we provide design review with a focus on mechanical and electrical constructability, owner-furnished equipment coordination, and the modular infrastructure strategies that let capacity be delivered in phases without disrupting existing tenants.

Segment

Edge and distributed: small footprint, long tail of consequences

Edge sites are smaller, but they are not simpler to commission. When a facility is unmanned or remotely monitored, a defect that slips through to operations means a field service call to a site that may be hundreds of miles from the nearest qualified technician.

We support prefabricated and containerized edge deployments, micro data centers, and distributed infrastructure from 100 kW to 2 MW. We provide rapid deployment commissioning built for sites where the on-site window is short and return visits are not an option. Remote monitoring setup, documentation completeness, and operator training are built into the commissioning scope, not treated as afterthoughts.

For edge deployments built on prefabricated or modular systems, we provide factory acceptance testing oversight before units ship. Finding manufacturing and integration problems while the equipment is still at the factory is a very different cost from finding them after installation on a remote site.

Depth

Technical capabilities

Data centers are built on the interaction between electrical, mechanical, controls, and increasingly renewable energy systems. Our commissioning and construction management teams work across all four.

Electrical

  • Utility interconnection and medium voltage distribution (4.16 kV to 34.5 kV)
  • Generator systems and paralleling switchgear - diesel, natural gas, and hybrid configurations
  • UPS systems in 2N, N+1, and N+2 architectures; battery energy storage systems
  • Low voltage power distribution, PDUs, RPPs, busway, static and automatic transfer switches
  • Power quality monitoring and electrical power management system integration

Mechanical

  • Computer room air conditioning and air handling units, in-row cooling, hot/cold aisle containment
  • Chillers - air-cooled, water-cooled, magnetic bearing, screw, and centrifugal configurations
  • Cooling towers, dry coolers, adiabatic and hybrid systems
  • Liquid cooling: direct-to-chip, cold plate, CDU systems, single-phase and two-phase immersion, rear-door heat exchangers
  • Pumping systems, glycol loops, hydronic balancing, testing, adjusting, and balancing services
  • Free cooling and economizer modes - airside and waterside

Controls and Automation

  • Building Management Systems and data center infrastructure management integration
  • Electrical power monitoring systems and energy management
  • SCADA systems, HMI development, alarm management
  • Sequence of operations validation and control narrative verification
  • PLC programming review, ladder logic validation
  • Protocol integration: Modbus, BACnet, LONworks
  • Control system cybersecurity and network segmentation review

Renewables and Energy

  • On-site solar PV systems - rooftop and ground-mount
  • Battery energy storage integration for renewable buffering and grid services
  • Microgrid controls, islanding, and black start commissioning
  • PPA and REC validation; grid interconnection and utility coordination

Lifecycle

Service offerings by project phase

Planning
  • Strategic planning and feasibility studies
  • Site selection and due diligence covering power, water, fiber, and risk
  • Basis of Design development and Owner's Project Requirements definition
  • Utility capacity evaluation and interconnection planning
  • Sustainability strategy including PUE, WUE, carbon, and ESG goals
Design
  • Design review for constructability, value, and risk identification
  • Electrical and mechanical systems peer review
  • Controls architecture assessment and sequence of operations review
  • Uptime Institute Tier certification support (Tier I through IV)
  • Modular and prefabrication strategy evaluation
Construction
  • Owner's representation and construction management
  • Mechanical, electrical, and plumbing coordination and trade sequencing oversight
  • Owner-furnished equipment logistics and quality inspection
  • Schedule management, critical path analysis, and recovery planning
  • Budget control and change order management
  • Quality in Action™ program execution across trade contractors
Commissioning
  • L1 - Factory Acceptance Testing at manufacturer facilities
  • L2 - Pre-commissioning: static checks, continuity, calibration
  • L3 - Commissioning: dynamic equipment testing and functional performance
  • L4 - Systems Integration Testing: multi-system interaction and failure mode verification
  • L5 - Integrated Systems Testing: full facility under load, N+1 and 2N validation
  • White space commissioning and IT load testing
Operations
  • Standard, maintenance, and emergency operating procedure development
  • Operator training and certification programs
  • Knowledge transfer and documentation handover
  • Post-occupancy commissioning and seasonal testing
  • Performance monitoring baseline establishment
  • Preventive maintenance program development

Standards

Standards we work to

Our work is executed against recognized international standards. When certification is the goal, we support the process from design through facility certification.

StandardScope
Uptime Institute Tier I to IVDesign and facility certification for reliability and redundancy
ASHRAE TC 9.9Thermal guidelines for data processing environments
TIA-942Telecommunications infrastructure standard for data centers
NFPA 75Protection of information technology equipment
NFPA 70 / NECNational electrical code compliance
NFPA 110Emergency and standby power systems
ASHRAE Guideline 0The commissioning process
ISO/IEC 27001Information security management
ISO 22301Business continuity management
LEED for Data CentersEnergy efficiency and sustainability